Customization: | Available |
---|---|
After-sales Service: | 1 Years |
Warranty: | 1 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters of generator set | |||
Machine group type number | XGT-300 | manufacturer | Quanzhou Gutai Machinery Equipment Co., LTD |
Frontal voltage | 400V/230V | Steady-state frequency adjustment rate | ≤ 1% |
A fixed frequency rate | 50HZ | Frequency stabilization time | ≤ 3 S |
Electric system | Three-phase four-wire system | Transient frequency adjustment rate | ≤ 1% |
Constant current | 540A | Wave motion rate | ≤ 1% |
Work factor number | 0.8 (lag) | Consider the heavy weight | 2700Kg |
Steady-state voltage adjustment rate | ≤±1% | Spin speed | 1500r/min |
Transient voltage adjustment rate | -15%~+18% | Reference overall dimension (Length * width * height) |
2980*1050*1800(mm) |
Voltage recovery time | ≤ 1S | Cold cooling square | Closed water cooling |
Fuel plate number | (Standard) 0# Light diesel (room temperature) | Noise (LP7M) | ≤117dB(A) |
Technical parameters of generator | |||
brand | Xingutai | Type number | XGTW-300-4(300KW) |
Excitation square type | Brushless, exciting, self-cooling | Protection level | IP22 |
Pressure regulating system | AVR automatic voltage regulation | Short time overcurrent | 3 to 5 Ie must be at least 5S |
Absolute edge level | H | Overloading energy | 1.5Ie at least 2 minutes |
Winding material | All copper wire winding | Number of phases and connection | Three-phase four-wire system |
Number of cylinders | 6 | Compression ratio | 16.8:1 |
Piston bore/piston stroke | 131mm/145mm | Starting square type | Electric actuation |
Oil consumption | ≤195g/kw.h | Start the electric source | DC 24V |
Exhaust volume | 11.72L | Adjustable speed square type | Electron speed adjustment |
Applicable ambient temperature | -10ºC~40ºC | Air intake system | Pressurized air-to-air cooling |
Diesel oil machine type | 6 cylinders in line, 4 strokes | Emission limits of pollutants | Non-road State Phase II |